占位边距

Products

Integrate the full range of core products, covering energy storage, charging piles, power protection, and other fields, providing detailed specifications and technical parameters

12kV Fast Current Limiter
  • 12kV Fast Current Limiter
Key attributes
Brand Rw Energy
Model NO. 12kV Fast Current Limiter
Rated voltage 12kV
Rated normal current 1250A
Series FCL
Product descriptions from the supplier
Description

Product Introduction

A switching device with extremely fast breaking speed

Reduce the investment in substations

  • Solve the short-circuit current problems encountered during the construction of new substations and the expansion of existing substations.

  • When paralleled with reactors, it is the most economical and effective way to limit short-circuit currents.

  • An ideal method for interconnecting switch cabinets and substations.

  • The only technical solution in most cases.

  • Reliability has been verified in the operation of thousands of engineering projects.

  • Has been put into use worldwide.

  • The short-circuit current will never reach the maximum expected peak value.

  • The short-circuit current is restricted during the initial rising stage.

Functions

With the growth in global energy demand, there is a need for higher-power power supplies,additional transformers and generators, and increased interconnection between independent power grids. This often leads to short-circuit currents exceeding the allowable values of equipment, resulting in dynamic and thermal damage to the equipment.Replacing existing switchgear and cable connections with new equipment that has a higher short-circuit current withstand capacity is usually technically infeasible or uneconomical for users. However, using fast current limiters to reduce short-circuit currents in new or existing systems not only solves the short-circuit capacity problem but also saves investment.Due to their slow operation, circuit breakers cannot provide protection against the excessive peak value of the first half-cycle of short-circuit currents in the system. Only fast current limiters can detect and limit the short-circuit current at the initial stage of its rise (within 1ms), so that the maximum instantaneous value of the actual short-circuit current flowing through is much lower than the expected peak value.Compared with complex conventional solutions, fast current limiters applied in transformer or generator feeder circuits, whether as bus connections or bypass current-limiting reactors,have technical advantages and economic benefits.In power plants, large industrial facilities, and grid substations, fast current limiters are ideal switchgear in all aspects for solving short-circuit current problems.

Main Parameters

Technical Parameters

Unit

1

2

3

4

5

6

7

Rated Voltage

V

750

12000

12000

17500

17500

24000

36000/40500

Rated Current

A

1250
2000
3000
4500¹)
5000¹)

1250
2000

2500
3000
4000¹)

1250
2000

2500
3000
4000¹)

1250
1600
2000
3000¹)

1250
2000
2500¹)

Rated Power Frequency Withstand Voltage

kV

3

28

28

38

38

50

75

Rated Lightning Impulse Withstand Voltage

kV

-

75

75

95

95

125

200

Rated Short - Circuit Breaking Current

kA RMS

Up to 140

Up to 210

Up to 210

Up to 210

Up to 210

Up to 140

Up to 140

Conductive Bridge Base

kg

10.5

27.5

65

27.5

65

27/31.5/33

60

Conductive Bridge

kg

17.0

12.5

15.5

14.5

17.5

19/19.5/24

42

Conductive Bridge Base and Conductive Bridge

Width mm

148

180

180

180

180

180

240

Height mm

554

651

951

651

951

740/754/837

1016

Depth mm

384

510

509

510

509

553/560/560

695

Typical Dimensions of Truck-Type Fast Current Limiter Cabinet

RatedVoltage

(kV)

RatedCurrent

(A)

RatedPowerFrequencyWithstandVoltage(kV)

RatedLightningImpulseWithstandVoltage(kV)

Height

(mm)

Width

(mm)

Depth

(mm)

Weight

(IncludingFastCurrentLimiterTruck)(kg)

12

1250

28

75

2200

1000 ²)

1634

1200

2000

2500

3000

4000 ¹)

17.5

1250

38

95

2200

1000 ²)

1634

1200

2000

3000

4000 ¹)

24

1250

50

125

2325

1000

1560

1300

1600

2000

2500 ¹)

Schematic Diagram of the Measurement and Control Device

T1 Current Transformer Matching the Fast Current Limiter

T2 Internal Intermediate Transformer of the Device

T3 Pulse Transformer

L1 Measuring Inductor

R1...R6 Adjustable Resistors

C1 Tripping Trigger Capacitor

Documentation Resource Library
Fast - Acting Current Limiter
Public.
Fast - Acting Current Limiter
Operation manual
English
Related Products
Related Solutions
Send inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Email
E-mail
Chat
Manager